For laboratory research use only. Not for human or veterinary consumption.

GLP-2 T - 60mg Lot DR60N061026: Certificate of Analysis (COA)

Paramount Peptides · tested Jun 28, 2026 by Accumark Labs · Most recent COA

HPLC purity
99.98%
Identity
Conforms
Test date
Jun 28, 2026

This page summarizes the third-party lab report for lot DR60N061026 of GLP-2 T - 60mg sold by Paramount Peptides. The lot number on this page should match the lot printed on the vial label. Don't rely on this summary alone: use the button to open the lab's own record and compare the lot, date and results.

Lot-matchedResults are tied to lot DR60N061026, not to the product in general.
Outside labTested by Accumark Labs, not by the vendor or by us.
Checkable at the sourceVerification code (Report ID) links to the lab's own record.
Original documentThe vendor's copy of the COA is shown below, unedited.

GLP-2 T - 60mg lot DR60N061026 test results, explained

Every result printed on this certificate, as reported by Accumark Labs, with a plain-English note on what the test measures. "Pass" and "specification" wording comes from the certificate; where the lab prints no pass/fail, we say so.

TestResult on the certificateWhat it measuresThis lot
HPLC purity99.984% · Double Regulator - Purity: 99.984% (spec > 98.0%; lab status: Conforms)HPLC separates the sample into its components; purity is the share of the detected signal that sits in the main peak. On its own it doesn't show which molecule that peak is. That's what the identity test is for.Meets the lab's specification (> 98.0%)
IdentityConformsMass spectrometry measures the molecular mass of what's in the vial and compares it with the declared compound. "Confirmed" means the lab found the expected compound.Reported as matching the declared compound
Quantity (measured content)70.62 mgHow much peptide the lab measured in the vial, compared with the amount printed on the label.118% of the 60 mg label amount
EndotoxinConforms (Spec: ≤ 5.0 EU/mL)Bacterial endotoxins are fragments of bacterial cell walls. The LAL assay measures them in endotoxin units (EU/mL); a pass means the result was under the lab's limit.Pass (as reported by the lab)
Rapid sterility screen (PCR)Conforms (Spec: Not Detected)A DNA-based (PCR) screen for common microbial contamination. It is a rapid screen, not a full sterility test. Test as named on the certificate: Rapid Sterility Screening (PCR).Pass (as reported by the lab)

Lot and report details

Lot / batch numberDR60N061026
Product (as labeled by vendor)GLP-2 T - 60mg
Labeled vial size60 mg
Testing laboratoryAccumark Labs
Sample received by labJun 23, 2026
Report dateJun 28, 2026
Sample size tested60.0 mg
Sample type (lab's label)Peptide
Verification code (Report ID)7VBF-FRTS
Lab-record checkLab's own record opened on Oct 7, 2026; lot number matched.
VendorParamount Peptides
VerifyOpen Accumark Labs's record ↗

Data notes: COA has 2 pages.

The certificate itself

Page 1 of the certificate of analysis for GLP-2 T - 60mg lot DR60N061026 (Accumark Labs)
Page 1 of the certificate (Paramount Peptides (vendor's copy)), saved here as an image so the page stays fast. Open the original image ↗ · Source ↗ (vendor lookup page; affiliate link) · Page 1 of 2 shown; the lab record has the full report

About Accumark Labs

An independent US analytical lab. Per its terms of use, Accumark Labs is a DBA of Valence Analytical LLC. Reports are published through AccuVerify, which shows each report from the lab's own records at a unique web address.

Accreditation: Accumark's website lists ISO/IEC 17025 accreditation as pending. We found no published accreditation certificate (checked Oct 7, 2026).

Tests: On the certificates here: HPLC purity, identity, quantity and, where ordered, endotoxin and a rapid sterility screen (PCR).

How to verify: Open accumarklabs.com/verify and enter the verification code (Report ID). The live record should show the same lot, dates and results as this page.

Open Accumark Labs's record ↗

Lab info from: accumarklabs.com · Accumark terms of use · checked Oct 7, 2026.

GLP-2 T - 60mg lot history at Paramount Peptides

All 25 certificates we have for this product from Paramount Peptides, newest first. The chart plots HPLC purity by report date (lots without a purity figure are left out). This lot is highlighted.

95%96%97%98%99%100%98%HTIR-0047: 99.814% (Sep 25, 2024)HTIR-0048: 99.849% (Sep 27, 2024)TIR60N11112024: 99.662% (Nov 22, 2024)TIR60N030425: 99.845% (Mar 18, 2025)TIR60N042225: 99.422% (Apr 30, 2025)TIR60N051225: 99.694% (May 23, 2025)TIR60N053025: 99.703% (Jun 8, 2025)TIR60N061025: 99.729% (Jun 23, 2025)TIR60N061625: 99.791% (Jun 25, 2025)TIR60N061925: 99.764% (Jun 30, 2025)TIR50N062425: 99.789% (Jul 3, 2025)TIR60N071725: 99.679% (Aug 6, 2025)TIR60N080125: 99.911% (Aug 19, 2025)T60N081525: 99.928% (Aug 26, 2025)T60N081925: 99.93% (Sep 2, 2025)T60N082025: 99.91% (Sep 2, 2025)T60N090925: 99.827% (Sep 23, 2025)T60N100825: 99.788% (Oct 22, 2025)T60N102925: 99.881% (Nov 12, 2025)T60N111325: 99.892% (Nov 28, 2025)T60N112525: 99.714% (Dec 9, 2025)T60N121725: 99.711% (Jan 8, 2026)T60N122325: 99.711% (Jan 9, 2026)TRIM75N012526: 99.872% (Feb 10, 2026)DR60N061026: 99.984% (Jun 28, 2026)Sep 25, 2024Jun 28, 2026
LotReport dateLabHPLC purity
DR60N061026Jun 28, 2026Accumark Labs99.98%
TRIM75N012526Feb 10, 2026Janoshik99.87%
T60N122325Jan 9, 2026Janoshik99.71%
T60N121725Jan 8, 2026Janoshik99.71%
T60N112525Dec 9, 2025Janoshik99.71%
T60N111325Nov 28, 2025Janoshik99.89%
T60N102925Nov 12, 2025Janoshik99.88%
T60N100825Oct 22, 2025Janoshik99.79%
T60N090925Sep 23, 2025Janoshik99.83%
T60N081925Sep 2, 2025Janoshik99.93%
T60N082025Sep 2, 2025Janoshik99.91%
T60N081525Aug 26, 2025Janoshik99.93%
TIR60N080125Aug 19, 2025Janoshik99.91%
TIR60N071725Aug 6, 2025Janoshik99.68%
TIR50N062425Jul 3, 2025Janoshik99.79%
TIR60N061925Jun 30, 2025Janoshik99.76%
TIR60N061625Jun 25, 2025Janoshik99.79%
TIR60N061025Jun 23, 2025Janoshik99.73%
TIR60N053025Jun 8, 2025Janoshik99.70%
TIR60N051225May 23, 2025Janoshik99.69%
TIR60N042225Apr 30, 2025Janoshik99.42%
TIR60N030425Mar 18, 2025Janoshik99.84%
TIR60N11112024Nov 22, 2024Janoshik99.66%
HTIR-0048Sep 27, 2024Janoshik99.85%
HTIR-0047Sep 25, 2024Janoshik99.81%

What to check on your vial

How to check this COA in under a minute

  1. Find the lot number on your vial label and confirm it reads DR60N061026.
  2. Open Accumark Labs's record with the button above, or go to accumarklabs.com and enter 7VBF-FRTS.
  3. Compare the lot number, test date, purity and identity result with the table above. They should be identical.
  4. New to COAs? Read How to read a peptide COA for what HPLC purity and mass spec identity mean.

Questions about lot DR60N061026

What HPLC purity did GLP-2 T - 60mg lot DR60N061026 test at?

Accumark Labs reported 99.98% HPLC purity for lot DR60N061026 in a report dated Jun 28, 2026.

How do I verify the COA for lot DR60N061026?

Go to accumarklabs.com and enter the verification code (report id) 7VBF-FRTS. The lab's own record should show lot DR60N061026 with the same dates and results as this page.

Is lot DR60N061026 the newest GLP-2 T - 60mg lot from Paramount Peptides?

It's the most recent GLP-2 T - 60mg certificate we have on file from Paramount Peptides as of Oct 8, 2026. Vendors can ship a newer lot before its certificate is posted, so check your vial label.

Does this certificate apply to my vial?

Only if the lot number printed on your vial reads DR60N061026 exactly. A certificate of analysis covers one lot; it says nothing about other lots of the same product.

Other lots and COAs

GLP-2 T - 60mg at Paramount Peptides

Lab-tested lot DR60N061026 · 99.98% HPLC purity · Accumark Labs

Use code SKYLER for 10% off
Shop at Paramount Peptides ↗

Affiliate disclosure: We earn a commission if you buy through the vendor links on this page, at no extra cost to you. Peptides & Coffee is an independent COA reference and is not owned by or affiliated with the vendors or labs listed. Lab results are published by the vendors and labs; we link to each lab's own verification record so you can check them yourself. Stock and lots change: the vendor may be shipping a newer lot than the one on this page, so check your vial label.